The output voltage of the UPS system in VAC.Free Visio Collections include any official, or unofficial collections that are freely offered on the web.- This is Allied Telesis' official set of Network stencils- This is Anue Systems's Visio stencil collection- This is APC's official set of Visio stencils- This is Arbor Networks's Visio stencil collection- This is Avaya's official set of Network stencils- This is Brocade's official set of Visio stencils- This is Cable Express's Visio stencil collection- This is Cablofil's Visio stencil collection- This is Cisco's official set of Network stencils. rateOfVoltageChange(10) - if the failure is due to the rate of change of selfTest(9) - if the UPS was commanded to do a self test. largeMomentarySpike(8) - if the line failure is caused byĪ rate of change of input voltage greater than ten volts per cycle. Rate of change of input voltage less than ten volts per cycle. smallMomentarySpike(7) - if the line failure is caused by a deepMomentarySag(6) - if the duration of the outage is less Than five seconds and the line voltage is between 40% of the smallMomentarySag(5) - if the duration of the outage is less Seconds and the line voltage is between 40% of the rated blackout(4) - if the duration of the outage is greater than five Rated output voltage and the low transfer voltage. brownout(3) - if the duration of the outage is greater thanįive seconds and the line voltage is between 40% of the highLineVoltage(2) - if the transfer to battery is causedīy an over voltage greater than the high transfer voltage. noTransfer(1) - if there is no transfer yet. The reason for the occurrence of the last transfer to UPS The current input frequency to the UPS system in Hz. The current internal UPS temperature in Celsius.īattery.temperature The UPS does not use smart cells then the agent reportsīattery.external_packs_count The number of external battery packs connected to the UPS. Indicates whether the UPS batteries need replacement.īattery.replace_indicator When the UPS batteriesĪre replaced, this value should be reset by the administrator.įor Symmetra PX 250/500 this OID is read-only and is configurable in the local display only.īattery.last_replace_date The date when the UPS system's batteries were last replaced The UPS battery run time remaining before batteryīntime_remainingīattery.voltage The remaining battery capacity expressed asīattery.capacity Installed has an internal error condition. The amount of run time in reserve at the time of low batteryĬan be configured by the upsAdvConfigLowBatteryRunTime.Ī batteryInFaultCondition(4)value indicates that a battery Load, and its services will be lost if power is not restored. Indicates the UPS will be unable to sustain the current Discovery rules Nameĭiscovery of the number of external defective battery packs. There are no template links in this template. Maximum output load in % for trigger expression. Minimum input voltage for trigger expression.

Maximum input voltage for trigger expression. Minimum input frequency for trigger expression. Maximum input frequency for trigger expression. The time interval for SNMP agent availability trigger expression. Maximum battery temperature for trigger expression. Minimum battery capacity percentage for trigger expression. No specific Zabbix configuration is required. Create a host for APC UPS Symmetra LX management IP as SNMPv2 interface.ģ. See Zabbix template operation for basic instructions.ġ. APC UPS Symmetra LX 16k (without external batteries).Note: please, use the latest version of the firmware for your NMC in order for the template to work correctly. The template to monitor APC UPS Symmetra LX by Zabbix SNMP agent. Source: APC UPS Symmetra LX SNMP Overview